近期我们有客户设备G104XVN01 V0 液晶屏出现亮线故障,退回我们分析原因和售后处理。下面我们就分享出来友达光电给我们的分析报告.
Step 1 問題定義 /改善主題與目標設定
Problem definition / Improvement subject & Target setup
General Information
No. | Item | Information |
1 | Customer (Site) | Xuhong |
2 | Panel Source | NA |
3 | RMA No. | NA |
4 | Customer Complain | H line |
5 | Project Name/AUO Model (Week Code) | 旭虹/G104XVN01 V0 (24/38) |
6 | AUO S/N(MFG Site | 1V4B83E01TZZZS0110 (S01) |
7 | Receive/Finish Date | 2025-10-09 / 2025-10-13 |
8 | Receive Q’ty | 1 |
9 | Defect rate | (Still waiting for feedback) |
10 | Customer:1.RA or Aging test 2.Reject site | Line reject |
11 | History | Have No Repair History In MA Process |
Step 2 現狀分析
Fact & Data Finding analysis
Failure description
Step 3 真因分析與驗證
Root cause analysis and verification
How :
1. 使用AU治具点亮正常,发现H line;
How :
2. 确认G104XVN01 V0 LCD外观无异常;
How :
3.OM下确认H line对应的位置为Y=157;
How :
4.OM下确认对应坐标的IC bonding未发现异常;
How :
5.OM下观察对应坐标的cell lead发现lead成膜异常;
Summary
1. 使用AU治具点亮G104XVN01 V0正常,发现H line;
2. 确认G104XVN01 V0 LCD外观无异常;
3. OM下确认H line对应的位置为Y=157;
4. OM下确认对应坐标的IC bonding未发现异常;
5. OM下观察对应坐标的cell lead发现lead成膜异常;
Conclusion
H line为cell lead成膜异常导致。
更多友达10.4寸液晶屏选型:https://www.hzxuhong.com/auo/10.4inch/